Special partner offer

Sika SikaSeal Fire Guard 295ml GREY - 4hr Fire Mate Intumescent Acoustic Acrylic Sealant

Sale price £2.22
Previously £2.96

Sika SikaSeal Fire Guard (GREY 295ml) 4 Hour Fire Rated Acoustic Acrylic Sealant – 902083 - Heat-Reactive Fire Sealant for Internal Joints,Door Frames, Partitions & Service PenetrationsMPN: 902083 | SKU: 902083 | Barcode: 5029347613648Colour: Grey | Size: 295mlSold in Single 295ml CartridgeFormerly Everbuild Fire Mate Intumescent Acrylic SealantOverviewThe Sika SikaSeal Fire Guard Grey 295ml is a fire-rated acoustic acrylic sealant designed for sealing internal joints and gaps where maintaining the integrity of a fire-resistant construction is important. The grey finish makes this version particularly useful around concrete, blockwork, metal framing and darker construction details where a bright white sealant may stand out unnecessarily.Supplied as a single 295ml cartridge that can be applied using a good quality standard size Sealant gun, it is a practical choice for repair work, smaller installations and individual fire-stopping details around door frames, partitions, plasterboard systems and suitable service penetrations. The non-sag consistency stays where it is applied, tools smoothly and remains flexible after curing, helping produce a neat joint without making application unnecessarily difficult.When exposed to heat, the sealant reacts by expanding to more than 150% of its original size, forming a protective char that helps restrict the passage of fire. In correctly designed and tested joint configurations, SikaSeal Fire Guard can provide up to four hours fire resistance.Fire performance is only part of the product's role. Sika also gives an average 24dB acoustic reduction between 100 and 3150Hz, making the sealant particularly useful around plasterboard panels, partitions and construction joints where unwanted sound transfer also needs to be reduced.Why Choose the Grey VersionGrey is a useful practical choice where the finished joint will remain visible against concrete, cementitious surfaces, blockwork, metalwork or similar darker construction materials. It can reduce the visual contrast around service openings and construction joints while still allowing the sealant to be overpainted where a different final finish is required. For a single cartridge listing, this makes it especially convenient for maintenance work, individual door-frame details and smaller fire-rated repairs where purchasing a full trade box would be unnecessary.Fire Performance in Correctly Designed JointsSikaSeal Fire Guard is tested to EN 1366-3 for penetration seals and EN 1366-4 for linear gap seals, with fire resistance up to four hours in specific tested configurations. The joint itself must still be correctly designed. Sika specifies fire-resistant joints between approximately 12mm and 50mm wide at half depth the sealant depth needs to be set using a polyethylene backer rod of the appropriate size for the joint gap, and the correct joint arrangement must be followed for the required fire performance. This is important because the stated four-hour rating is not an automatic rating for every bead or gap size.Acoustic Sealing as Well as Fire ProtectionSmall gaps around partitions, plasterboard and framing can allow sound to pass through even when the main wall construction performs well acoustically. The firm but flexible seal created by Fire Guard helps close these leakage paths, with Sika reporting an average noise reduction of approximately 24dB between 100 and 3150Hz. This gives the product a useful dual role in internal fire-rated construction where both fire integrity and acoustic performance matter.Always read the manufacturer's latest Product Data Sheet, Safety Data Sheet and relevant fire-test documentation before first use to confirm that the proposed joint configuration provides the required fire performance.Understanding the 4 Hour RatingThe phrase “up to 4 hours” refers to specific joint and penetration arrangements tested to the relevant fire standards.Actual fire resistance depends on factors including the substrate, joint width, seal depth, orientation and complete construction. For this reason, Fire Guard should not be treated as automatically providing a four-hour rating simply because a bead has been applied. The installation must correspond with an appropriate tested design.Working with Larger GapsWhere the construction contains a substantial void, simply filling the complete depth with acrylic sealant may not represent the correct tested arrangement. Sika advises that large voids should first be filled with Everbuild Firefoam B1 where appropriate, before the Fire Guard joint is completed. The complete fire-stopping detail should always be checked against the relevant test or certification requirement before work starts.Applications: The grey single cartridge is particularly useful where: only a limited quantity is needed or where the finished joint needs to blend with darker construction materials.; Fire-Rated Partition Walls: Seal suitable joints and gaps in internal partition systems.; Door F...

Share

More from Sika

View more

More from sealantsandtoolsdirect.co.uk

View more